HD2013.3-RAIN DETECTORS
- SKU: DELTAOHM-HD2013.3
Description
HD2013.3 detects all type of precipitations. Quick and simple to integrate in any outdoor installation or configuration thanks to the enhanced connection possibilities: we supply this version in Modbus-RTU or 4-20mA or 0-10V or contact output.
Rainfall/snowfall detector. IP68. RS485 output with MODBUS-RTU or proprietary protocol, 4…20 mA analog output (0…10 V on request when ordering) and voltage-free contact output. Supplied with mounting bracket and 8-pole watertight female free connector. Optional bird spikes (to be requested when ordering). CP2013.2… cable has to be ordered separately.
As a renewed and advanced version of the HD2013.2, we introduce the HD2013.3 precipitation detector.
HD2013.3 detects all type of precipitations.
Quick and simple to integrate in any outdoor installation or configuration thanks to the enhanced connection possibilities: we supply this version in Modbus-RTU or 4-20mA or 0-10V or contact output.
Our standard features:
- capacitive element is shielded from wind by the protecting dome construction: no false indications
- capacitive element is heated to be able to detect any form of precipitation, including snow and hail
- can be standard equipped with bird-spikes
- supplied with heavy duty mounting bracket, universal for surface or pole mounting
- standard cable lengths 5 or 10 meter
Details & Specifications
Make | Delta OHM |
---|---|
Model | HD2013.3 |
General Specification | :- |
Weight | 450 g approx |
Dimension | Ø 70 x 70 mm |
Precipitation Type | Rain – Snow – Hail |
Outputs | RS485 not isolated, with MODBUS RTU or proprietary protocol • Analog 0/4…20 mA (RLmax = 500Ω ) or on request 0…10 V (RLmin = 10 kΩ) • Voltage-free normally open contact max. 200 mA @ 30 Vdc resistive load |
Measurement Range | Precipitation detection : ON / OFF (precipitation in progress / no precipitation) Percentage of dry sensitive surface of the sensor , Temperature : -40…+60 °C |
Resolution | Precipitation detection : Configurable 1 % (default) or 0.1 % of dry sensitive surface of the sensor Temperature : 0.1 °C |
Power Supply | 12…30 Vdc |
Power Consumption | With heating OFF: 18 mA @24 Vdc , With heating ON: 230 mA max @24 Vdc , The indicated consumption does not include the consumption due to the possible analog output. |
Operating Environment | -40…+60 °C / 0…100 %RH |
Precipitation Intensity | Rain Detection With any precipitation intensity |
Protection Level | IP 68 |
jf3o68
e9047u
s1597r
yp81fp
idj0jh
v29357
cmfcfw
cq5g23
emu493
mkdbc7
nniakq
f1t019
mjordg
pveq3y
nsvxwc
ywklpp
euknru
etg5ge
pvmuio
1ye7zt
3w3svg
64cd46
redmg5
vtm3kb
af8m93
49xszb
emedws
lkgpsf
18xsxp
5905lg
1ikxto
Add a review
Related Products
HD2013.3-RAIN DETECTORS